Magnetically Levitated Vertical Axis Wind Turbine


Pitched Style Roof

·          Vertical Axis Wind Turbine with sails that can receive wind forces from any direction.  Including up and down winds.
·         Magnetically Levitated – reducing friction, noise, vibration and energy loss.
·         Axial Flux Alternator – Allows it to generate large amounts of electricity at low rotational speeds.
·         Roof Mounted – Does not require a tower, allows the wind turbine to take advantage of air-compression velocity increases from roof effect.
·         Programmable Variable Coil Resistance – allows the increase of magnetic resistance as the wind speed increases.  This reduces the cut-in wind speed required for electricity generation.
Overcoming Challenges of the Conventional VAWT concept: 
·         The ‘conventional’ VAWT has bearings to change   
o    MVAWT uses magnet levitation, which does not need regular maintenance.
·         MVAWT starts at low wind speeds
o    Variable resistance coils - controls Drag.
·         MVAWT accepts wind from multiple directions
o    Sail design accepts all winds even from above.
·         The ‘conventional’ VAWT suffers torque ripple effect.
o     MVAWT has no drive train to torque.
·         The ‘conventional’ VAWT suffers wear and tear from vibration
o    The MVAWT is magnetically levitated, so there is no vibration. 

























There are five main aspects that affect the output of our wind turbine:

·         Wind Speed – Site wind characteristics.
·         Roof Effect - The shape of the roof can increase or decrease the performance
·         Coil Output – Number of coils
·         Sail Size – surface area and configuration of the sails
·         Inverter – the maximum amount of electricity is limited by the size of the inverter.


10 KW - Model MW-2200
 
Product
Max Cap
Estimated Monthly Production
Start Order Date
Est. Delivery Date
MW-2200™
10 kW
2200 kWh
August 2008
1st Quarter 2009
·   Productivity: 2200 kWh/month in a 13 mph average wind, on a house with a UDA factor of 1.9. (See Wind Energy for a discussion on UDA).
·   Name Plate: Median 10 kW rated output in 28 mph wind at sea level with 80% relative humidity on a house with a UDA factor of 1.9.
·   Weight: 800 - 1000 pounds depending on sails selected.
·   Height: 8-12 feet depending on sails selected.
·   Diameter: 10-14 feet depending on sails selected.
·   Sail Sizes:
·         Small Sail  9’8” X 10’2”
·         Large Sail 12’6” X 14’
·         Hawaii Sail 8’ X 14’
·   Cut-In Speed: Less than 5 mph, on a house with a UDA factor of 1.9.
·   Top Speed: Maximum rated speed 120 mph at turbine.
·   Temperature:
·         Turbine Operating Temperature -45° F to 130°F
·         Inverter Operating Temperature 32° F to 113° F
·   Hook-up :
·         Small FRP enclosure/J-box (6”X6”X4”) that fits under the roof modification, and to which conduit can be channelled for the down-wiring.
·         Output Wiring is 14-4 wiring from the turbine to the inverter. 
·   Electrical, from Turbine:
·         Voltage 0-480 volts
·         Amperage 0-10 Amps
·         Wattage max depends on number of coil packs selected. Calculated with sail size.
·   Electrical, from Inverter:
·         MEDCOM/CPE_ AC/AC converters modules with grid connection each rated at 10kW
·         Installed in a wall mounted enclosure for 10 kW Wind system with output Voltage from permanent magnets, 3-phase axial flux alternator.
·         Converter specification:
·         Wall Mounted
·         Sine wave grid connected inverter with uo to 50% overload capacity
·         Inverter output Voltage: Single phase, 208 Vac, +10% / -15%, 240 Vac, +10% / -15% and 220 Vac, +10% / -15%
·         Rated Frequency: 50 Hz. +0.5Hz and 60 Hz, +0.6Hz
·         Rated Output Power: 10 kW
·         Rated Output current harmonics: <4%
·         Anti-islanding contactor between inverter and electrical grid
·         AC/DC and DC/AC conversion efficiency between 90% and 95%
·         Power Factor: Unity P.F.
·         Ambient temperature: 0 to 45C
·         Auto reconnect (restart) after power interruption
·         Includes dumpload resistors
·         Includes DC terminals for connection to optional DC/DC converters and batteries, if required.
     Note: batteries and optional DC/DC converters not included in price.
·         Approvals: cUL, CE. Meets UL1741 and IEEE1547.
·         Equipment manufactured in ISO facility
·   Maintenance and Operation Costs: Minimal